JCE Software Chemistry Comes Alive!
Keywords beginning with R

The first column contains titles of relevant pages (and links). The second column indicates the context of the page. This may help you distinguish between pages with similar titles.

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | All Words


recording data
Measuring

recording spectrophotometer
Double-Beam Recording SpectrophotometerMeasuring>Spectroscopy

recrystallization
Separating and Purifying
DescriptionSeparating/Purifying>Filtration
Hot Filtration ProcessSeparating/Purifying>Filtration>Gravity>Processes
RecrystallizationSeparating/Purifying
Inducing Crystallization by NucleationSeparating/Purifying>Recrystallization>Single-Solvent>Cool the Solution
Vacuum FiltrationSeparating/Purifying>Recrystallization>Single-Solvent>Filter+Dry Crystals

reduced pressure
DistillationSeparating/Purifying
Reduced-Pressure Distillation ProcessSeparating/Purifying>Distillation>Reduced Pressure
Using a Rotary EvaporatorSeparating/Purifying>Distillation
DescriptionSeparating/Purifying>Filtration
Creating a Vacuum by Connecting to a Vacuum PumpSeparating/Purifying>Filtration>Vacuum>Apply+Release Vacpump
Creating a Vacuum by Connecting to a Vacuum PumpSafety>Handling Glassware

reflux
Reflux: Reactions at Constant TemperatureManipulate/Transfer>Heat/Cool
Simple DistillationSeparating/Purifying>Distillation
Add Solids to the Reflux FlaskSafety>Heating+Hot Items

ring stand
Heating an Erlenmeyer flaskManipulate/Transfer>Heat/Cool>Gas Burner
Gas-Burner SafetyManipulate/Transfer>Heat/Cool>Gas Burner
Attach the FlaskManipulate/Transfer>Heat/Cool>Reflux
ThermometerMeasuring>Temperature
Filling the Buret With Titrant (Procedures and Mistakes)Measuring>Titration>Procs+Mistakes>Prep for Titration
Filling the Buret With Titrant (Procedures and Mistakes)Measuring>Volume>Buret>Use+Mistakes
Using a Separatory Funnel (Version 1)Separating/Purifying>Extraction
Folding Filter PaperSeparating/Purifying>Filtration>Gravity
Assembling EquipmentSeparating/Purifying>Filtration>Vacuum
Separatory Funnel SafetySafety>Handling/Mixing
Making Separatory Funnel ProtectorsSafety>Handling Glassware
Heating an Erlenmeyer flaskSafety>Heating+Hot Items>Safety

rinse
Obtaining a Liquid Sample (Procedures and Mistakes)Manipulate/Transfer>Transfer
Solid from Dish to Beaker to Volumetric FlaskManipulate/Transfer>Transfer>Quant>Solid
Solid from Dish to Volumetric FlaskManipulate/Transfer>Transfer>Quant>Solid
Mohr PipetManipulate/Transfer>Transfer>Quant>Liquid
Transferring a 25-Milliliter SampleManipulate/Transfer>Transfer>Quant>Liquid>Vol Pipet
Conductivity MeterMeasuring>Electrical Properties
Weigh in a Weighing DishMeasuring>Mass>Balance+Draft Shield>Weighing Vessels
pH MeterMeasuring>pH
Preparing the Cuvette and Placing the Sample in the SpectrophotometerMeasuring>Spectroscopy>Spec 20
Placing a Sample in a Single-Beam InstrumentMeasuring>Spectroscopy>Single-Beam
A Complete Acid-Base TitrationMeasuring>Titration
Buret Tip is Not RinsedMeasuring>Titration>Procs+Mistakes>Prep Buret>Rinse w Water
Obtaining Titrant (Procedures and Mistakes)Measuring>Titration>Procs+Mistakes>Prep for Titration
Rinsing the Buret with Titrant (Procedures and Mistakes)Measuring>Titration>Procs+Mistakes>Prep for Titration
Rinsing and Filling a BuretMeasuring>Volume>Buret
Buret Tip is Not RinsedMeasuring>Volume>Buret>Use+Mistakes>Rinse w Water
Rinsing the Buret with Titrant (Procedures and Mistakes)Measuring>Volume>Buret>Use+Mistakes
Mohr Pipet TopicsMeasuring>Volume>Pipets>Mohr Pipet
Rinsing the Mohr Pipet with Sample (Procedures and Mistakes)Measuring>Volume>Pipets>Mohr Pipet>Use+Mistakes
Transferring a 25-Milliliter SampleMeasuring>Volume>Pipets>Volumetric Pipet>Topics
Rinsing the Volumetric Pipet with Sample (Procedures and Mistakes)Measuring>Volume>Pipets>Volumetric Pipet>Using+Mistakes
Using a Volumetric FlaskMeasuring>Volume>Vol Flask
Dissolving a Solute in an Erlenmeyer FlaskMeasuring>Volume>Vol Flask>Using>Dissolve
Solid from Dish to Beaker to Volumetric FlaskMeasuring>Volume>Vol Flask>Prep Solution
Solid from Dish to Volumetric FlaskMeasuring>Volume>Vol Flask>Prep Solution
Removing Supernatant and Washing PrecipitateSeparating/Purifying>Centrifuge
Cleaning the SyringeSeparating/Purifying>Chromatography>Gas Chrom
Shaking and VentingSeparating/Purifying>Extraction>Using Sep Funnel V2
Gravity Filtration with Folded PaperSeparating/Purifying>Filtration>Gravity>Processes
FilteringSeparating/Purifying>Filtration>Vacuum
Solid from Dish to Beaker to Volumetric FlaskQuant Transfer
Solid from Dish to Volumetric FlaskQuant Transfer
Transferring a 25-Milliliter SampleQuant Transfer
A Complete Acid-Base TitrationQuant Titration

rotary evaporator
DistillationSeparating/Purifying

rough titration
Titration TechniquesMeasuring>Titration

rubber bulb
Transferring a 25-Milliliter SampleManipulate/Transfer>Transfer>Quant>Liquid>Vol Pipet
Inspect the Pipettor and Select the VolumeManipulate/Transfer>Transfer>Quant>Liquid>Digital Pipettors
Transferring a 25-Milliliter SampleMeasuring>Volume>Pipets>Volumetric Pipet>Topics
Inspect the Pipettor and Select the VolumeMeasuring>Volume>Pipets>Digital Pipettors
Transferring a 25-Milliliter SampleQuant Transfer

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | All Words